Tlux — Lighting Design Software فارسی Log in to the software
Lighting design software

Lighting design, with engineering precision
from plan to order list

Send a PDF plan and the spaces are recognised automatically. The number and position of the lights are suggested according to the standard lighting level. You see the result on a lux map and a 3D rendering before installation, and receive the ceiling cutting plan for the electrician and the order list.

Tlux lighting software on a laptop and phone, with the plan and light layoutOne project, on laptop and phone — no installation
3D rendering of lighting for the whole residential unit3D rendering of the whole unit with light rays
Lux map of illuminanceLux map before installation
Automatic space detection from planAutomatic space detection from plan
Custom chandelier designCustom chandelier and decorative light design
Outdoor and facade lightingOutdoor and facade lighting
EN 12464-1Basis: lighting and glare
PDF ← ceiling cutFrom the architect's plan to the electrician's drawing
Real catalogueLumen, watt and product IES files
OfflinePhone, tablet and laptop
Try it yourself

Move the lights; the light is calculated instantly

A 6 × 4.5 m living room. Drag the lights and move the golden line in the middle to see the raw plan and the lighting map side by side.

Raw planLighting mapDrag the lights with your finger
—Average illuminance (lx)
—Uniformity U₀
—Number of lights
—Total power (W)
Light
Count
0100200300400+ lx
The living room target is about 150 lux. This demo is a simplified version of the engine; the software itself also calculates ceiling and wall reflection, furniture shadows and each luminaire's IES file.
Features

Every stage of lighting design, on your own plan

For a residential unit, villa, shop, office, restaurant and hotel — with the same products that will be installed.

Automatic space detection from AutoCAD PDF plan
01

Automatic space detection from PDF plan

Send an AutoCAD PDF or a photo of the plan. The walls are read, and the rooms are separated and named. You no longer need to draw the spaces one by one.

  • PDF, plan photo or hand sketch
  • Crop the needed part of an A3 or A0 sheet
  • The type of each space sets its target lux
Precise halogen layout with dimensions to the wall
02

Halogen placement by standard lux

Smart placement suggests the number and position of the lights for the lighting each space needs. During manual moves, the distance to the wall and to the nearest light is shown instantly.

  • Halogen, linear, magnetic, wall light and concealed light
  • Keeps distance from the TV, cabinets and ceiling services
  • Sharp zoom on large plans
Lux illuminance map in false colour
03

Lux map before installation

The colour lux map shows where the space is dim or bright. It gives the average, minimum and uniformity of the work-plane illuminance — a basis that can be compared with DIALux.

  • Direct calculation and reflection from ceiling, walls and floor
  • Adjustable reflectance and maintenance factor
  • Vertical and cylindrical illuminance for faces and walls
3D rendering of lighting for the whole residential unit
04

Realistic 3D rendering of the whole unit

All spaces with real light, furniture shadows and concealed light in one view — for presenting to the client and deciding before the ceiling is built.

  • Realistic view, false colour and presentation mode
  • Show all the project's spaces at once
  • Smooth performance on a phone
Adjusting spot angle on a clothing shop rail
05

Adjusting the angle of adjustable lights

Select a light and tap a rail, board or showcase. The rotation angle and direction are calculated and the light spot on the target is shown — no trial and error.

  • Aim all the spots near a rail at one point
  • Lux on horizontal and vertical surfaces
  • Warning for steep angles and light in the customer's eyes
UGR glare check: diffuser vs darklight
06

Glare check per EN 12464-1

From the real positions of people — on a sofa, in bed, behind a desk — the UGR is calculated: a glare map on the plan, the 180° view of each person, the cross-section of each light with its beam angle, and a suggestion of low-glare luminaires from your own catalogue.

  • CIE 117 and CIE 147 methods
  • Checks the minimum beam angle of the luminaire
  • Automatic correction by replacement or relocation
Lighting control with goodnight and leave-home scenes
07

Smart lighting control

Switch wiring, scenes and the Zigbee network are designed on the same plan: how many bridges each space has, which light is in which scene, and network coverage across the whole unit.

  • Arrive, leave, good night and cinema scenes
  • Zigbee network coverage and route calculation
  • Smart equipment shopping list with prices
Cascade custom chandelier on a staircase
08

Custom chandelier design

Cascade, linear or ring chandeliers with any number of strands, length and layout, with an order sheet for manufacturing.

Facade and outdoor lighting with wall and pole lights
09

Facade and outdoor lighting

Recessed, pole-mounted, wall and step lights, with the IP rating suitable for each point.

Lighting catalogue and order list
10

Real catalogue and order list

Luminaires with lumens, watts, beam angle and IES file; the order list with quantities and prices, automatically.

Lighting technical report and ceiling cutting plan
11

Technical report and ceiling cutting plan

Halogen positions centimetre by centimetre for the electrician, and a report for the client, with your own company name and logo.

Before buying a light

See which light catches the eye

The view of someone sitting on a sofa looking ahead. All three luminaires give the same 900 lumens and sit in the same place; only the frame type differs. The UGR figure is calculated with the standard CIE 117 formula.

—UGR
Workflow

From plan to handover, in five steps

  1. Upload the planPDF, photo or sketch; set the scale with one or two dimensions
  2. Confirm the spacesAutomatic detection of rooms and their use
  3. Choose a luminaireFrom the catalogue; smart or manual placement
  4. Check the resultLux map, 3D rendering and glare
  5. HandoverCeiling cutting plan, order list and report
Comparison

Tlux alongside other methods

The calculation is on the same standard basis; the difference lies in the architect's workflow from plan to execution.

TluxExternal software
Like DIALux
Manual design
Excel and experience
Interface and report in Persian✓English—
On phone and tablet, no installation✓Windows desktop only—
Automatic space recognition from a PDF plan✓Drawing or entering the plan—
Illuminance and uniformity per EN 12464-1✓✓Approximate
Glare (UGR) from the real positions of people✓✓—
Catalogue of brands in the Iranian market✓Limited—
Ceiling cutting plan centimetre by centimetre for the electrician✓ ReadyWith manual adjustmentManual
Order list with prices✓—Manual
Learning timeA few hoursLong—
Who it is for

For anyone who needs to know, before installation, how many lights, where, and of which model

ArchitectInterior designerLighting designer and consultantLighting shop and distributorElectrical contractorBuilder and developer
Plans

The plan that suits you

Both editions work with the real product catalogue and the standard calculation. Contact us for prices and activation.

Semi-complete edition

  • Up to 3 spaces per project
  • Space detection from plan, smart and manual placement
  • Lux map and technical tables
  • Glare check from people's positions
  • Order list with prices
  • 3D view and presentation rendering
  • Printed report and PDF
  • Circuit and electrical load table, IES file
  • Smart control and sound system
Request the semi-complete edition
Our suggestion

Full edition

  • Unlimited spaces per project
  • All features of the semi-complete edition
  • Realistic 3D view and presentation rendering for the client
  • Printed report and PDF with your company's name and logo
  • Ceiling cutting plan, circuit and electrical load table
  • Upload the manufacturer's IES file
  • Zigbee smart control and sound system
Request the full edition
Free tool

How many halogens does this room need?

Enter the size and type of the space to get the number of halogens, their spacing from each other and from the walls, and the resulting lux.

Calculate halogen count and spacing
  • 8 halogen20 m² living room, 10 W halogen
  • 125 cmHalogen spacing along the room
  • 157 lxAverage illuminance obtained
Articles

Blue light, circadian rhythm and choosing the right light for each space

What light does the eye receive to set the body clock?

The eye is not only for seeing. The retina has cells called ipRGC that contain melanopsin and tell the body's internal clock (circadian rhythm) whether it is day or night. The highest sensitivity of these cells is around 480 nm, in the blue range. 480 nm that is, in the blue range.

The action spectrum of non-visual light, including setting the body clock, is in the range of 447 to 484 nm and has the greatest effect; in other words, its peak is in the blue. At night, the same blue light causes the largest drop in melatonin (the sleep hormone) secretion, which is why night-time blue light harms sleep the most.

Blue light in the day is good, at night it is not

During daytime hours, light with enough blue content helps with alertness, concentration and setting the body clock. That is why whiter, cooler light suits offices and hospitals during the day. In the evening and at night, however, the same light stops the body from "hearing" the signal to sleep early.

CIBSE and SLL guidance (Integrated Lighting Position Statement, 2026) proposes these practical limits, measured by melanopic light intensity (melanopic EDI) at eye level:

TimeSuggested limit (melanopic EDI at eye level)
Daytime during occupied hoursAt least 250 lux
Three hours before sleepAt most 10 lux
During sleepAt most 1 lux (the closer to zero, the better)

The key point is that colour temperature alone does not show how much blue light a source contains; two sources with the same colour temperature and the same lux can have very different melanopic content. That is why CIE and CIBSE recommend specifying the melanopic index in design, not just the kelvin value.

Cornea and lens: what we need to know

The cornea and lens absorb part of the light before it reaches the retina. Based on measurements by Ambach et al. (1994), the cornea almost completely absorbs ultraviolet light; its transmission reaches 1% at about 291 to 298 nm. The lens also absorbs strongly at about 389 to 414 nm, at the violet–blue edge. So most blue light (from about 440 nm upward) passes through both, and the lens mainly reduces the short-wavelength blue edge.

That the lens becomes yellower with age and blue transmission decreases is a known phenomenon, but this article does not yet cite a confirmed source for it.

The absorption figures come from the study by Ambach et al. (1994). Age-related change in lens transmission was not examined in that source and should be checked against a separate source before use in an official report.

Suitable light for each space

SpaceSuggested colour temperatureDesign note
Office and workspaceNeutral to cool (about 4000 to 5000 K)Daytime: enough light at eye level, low glare on the screen
Daytime sections of hospitals and examination roomsNeutral to coolClinical accuracy and true colour matter; high CRI (90 and above)
Patient room and hospital night corridorWarm (about 2700 to 3000 K), with low light levelsAt night, bright blue-rich light harms the patient; low warm light for the patient's sleep
Living room and bedroomWarm (2700 to 3000 K)Dim in the evening and at night; the bedroom is darker at night
Kitchen and home workNeutral (about 4000 K)Task light on the work surface, not in the eyes
Gallery, clothing shop, hair salonDepends on the product; usually neutralHigh CRI (90 and above) so the true colour of the product is seen
Garden and outdoor spaceWarmThe least light needed, with glare control and no light spill into the sky or the neighbours' property

The colour temperature and CRI figures in this table are practical suggestions; they do not come from a specific hospital standard, and an official source for hospital colour temperature has not yet been found. Before installation, check them against the local standard or the official text (such as EN 12464-1).

Sources:

Colour temperature, CRI and glare: three numbers you should know

Colour temperature (K) Describes the feel of the light; the higher the number, the whiter and cooler the light. CRI Shows how true the light renders colours; about 80 is recommended for general use, and 90 and above for spaces where colour matters. Glare Occurs when a direct light source is in the field of view; beam angle, mounting height and the use of a bowl or diffuser reduce it.

The practical point is to choose all three together: cool light with low CRI makes colours look dull, and warm light with high glare makes the space harsh and uncomfortable.

In Tlux: The colour temperature and CRI of each luminaire are read from the catalogue and appear in the technical report next to lux and uniformity. Free halogen count calculator
Frequently asked questions

Common questions

Is Tlux a Persian-only program?

Yes. The whole environment, the reports and the ceiling cutting plan are in Persian and right-to-left. For projects outside Iran, English output is also available.

Do I need to install anything?

No. It opens in the browser on your phone, tablet or laptop, and you can add it to your home screen. It also works offline.

How is it different from DIALux?

Lighting and glare calculations use the same standard basis, but the workflow is simplified for architects: you send a PDF plan, the spaces are detected automatically, the luminaire is chosen from a real product catalogue, and the output is a ceiling cutting plan for the electrician plus an order list.

Does the report carry my company's name and logo?

Yes. In the full edition, your company name and logo are placed on the report letterhead and drawings.

How do I get a subscription?

Call or message 09140129007 and your username and password will be activated.

Demo, subscription and support

To see the software on your own project, activation, or a technical question, call or send a message.